GROUTED SLEEVE CONNECTION FOR PRECAST CONCRETE MEMBERS
نویسندگان
چکیده
منابع مشابه
Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading
In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the h...
متن کاملDesign Considerations for the Connection of Precast Concrete Structures
The structural integrity of precast concrete buildings depends mainly on the connections between the precast structural components. Large precast concrete panels are used extensively in North America for low, medium, and highrise construction due to their ease and speed of assembly, and high quality control. This paper presents the results of twenty-two prototype specimens tested to investigate...
متن کاملPrecast Concrete Elements
Lattice-girder floor slabs and double-wall elements have been successfully used in building and industrial construction for decades. These precast elements of 50 – 70 mm thickness serve as permanent formwork for the subsequently added in-situ concrete creating a monolithic structure. The high prefabrication level allows the construction period to be significantly minimized. The main goal is the...
متن کاملPerformance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملExperimental study of grouted sleeve lapping connector under tensile load
The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load-displacement curves of the specimens are discussed in the study. Two equations are proposed for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Stavební obzor - Civil Engineering Journal
سال: 2020
ISSN: 1805-2576
DOI: 10.14311/cej.2020.04.0038