Gravimetric Determination of Nickel with Salicylaldehyde Thiosemicarbazone
نویسندگان
چکیده
منابع مشابه
GRAVIMETRIC DETERMINATION OF NICKEL WITH CYCLOHEXYLIDINE-AMMONIUM-2-AMINOC YCLOHEXY LIDINE- 1-CYCLOHEXENE-1-DITHIOCARBOXYLATE
Cyclohexylidine-ammonium-2-aminocyclohexyline-l-cyclohexee-l- dithiocarboxylate (CCCD) is employed for the gravimetric determination of Ni (II). In neutral or ammoniacal solutions, the metal forms a violet precipitate with the reagent which can be weighed as Ni (C13H18NS2)a2f ter drying at 115 - 120?C Using this procedure, the nickel content of steel samples can also be determined accurate...
متن کاملDetermination of nickel in alloys and plant leaves with salicylaldehyde 3-oxobutanoylhydrazone by spectrophotometry.
A simple and highly sensitive reagent of salicylaldehyde 3-oxobutanoylhydrazone (salicylaldehyde acetoacetic acid hydrazone, SAAH) was synthesized and studied for the spectrophotometric determination of nickel in detail. In the pH range 6, which greatly increased the selectivity, nickel reacted with SAAH to form a 1:1 yellow complex, having a sensitive absorption peak at 405 nm. Under the optim...
متن کاملSpectrophotometric determination of nickel(II) with 2-hydroxy-3-methoxy- benzaldehyde thiosemicarbazone
2-Hydroxy-3-methoxy benzaldehyde thiosemicarbazone has been synthesized, characterized and its analytical application investigated. It reacts with nickel(II) in aqueous solution at pH 4.0-8.0 and at room temperature to form a yellow coloured ML (1:1) complex with absorption maximum at 410 nm and molar absorptivity 2.05×10 l mol cm. Beer’s law is obeyed in the range of 0.058-2.347 μg ml of Ni(II...
متن کاملgravimetric determination of nickel with cyclohexylidine-ammonium-2-aminoc yclohexy lidine- 1-cyclohexene-1-dithiocarboxylate
cyclohexylidine-ammonium-2-aminocyclohexyline-l-cyclohexee-l- dithiocarboxylate (cccd) is employed for the gravimetric determination of ni (ii). in neutral or ammoniacal solutions, the metal forms a violet precipitate with the reagent which can be weighed as ni (c13h18ns2)a2f ter drying at 115 - 120?c using this procedure, the nickel content of steel samples can also be determined accurately. t...
متن کاملGravimetric determination of pipette errors
In chemical measurements (for instance in titrimetric analysis) it is very important to precisely measure amount of liquid, the measurement is performed with use of various measuring vessels. Presently laboratories use all kinds of glass measuring vessels like: beakers, flasks, etc., for measurement of bigger volumes of liquid, and in case of small volumes glass pipettes. Glass pipettes have be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the Chemical Society of Japan
سال: 1989
ISSN: 0009-2673,1348-0634
DOI: 10.1246/bcsj.62.3763