Graphite furnace atomic absorption spectrometry of uranium by use of a tantalum boat
نویسندگان
چکیده
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملDirect determination of zinc in serum by Zeeman atomic absorption spectrometry with a graphite furnace.
We developed a precise and accurate graphite furnace atomic absorption spectrometric method for the direct determination of zinc in serum. Serum samples are analyzed after 20-fold dilution with water of ultrapure analytical grade. No other reagent is used, from the moment of sampling until measurement. During atomization, the argon flow is kept at 150 mL/min instead of gas stop, to decrease the...
متن کاملThe Analysis of Trace Elements in Honey by Flame and Graphite Furnace Atomic Absorption Spectrometry
متن کامل
Concanavalin A-bound selenoprotein in human serum analyzed by graphite furnace atomic absorption spectrometry.
We developed an assay for the direct determination of selenium in serum with a Perkin-Elmer Model 4100ZL Zeeman atomic absorption spectrometer and Ag-Cu-Mg modifier. We used this assay to analyze concanavalin A-bound selenoprotein (CABSP) in human serum after concanavalin A (ConA) affinity chromatography. The CABSP was identified as a single-chain glycoprotein of 57.3 kDa. Carbohydrate units we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1979
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.28.3_133