Gradient preemphasis calibration in diffusion‐weighted echo‐planar imaging

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gradient preemphasis calibration in diffusion-weighted echo-planar imaging.

This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions....

متن کامل

Echoplanar chemical shift imaging.

A novel method of chemical shift imaging utilizing echoplanar imaging (EPI) has been developed for the purpose of improving the spatial resolution of metabolite images for the specific goal of high spatial resolution mapping of neuronal content. An EPI sequence was modified to allow temporal offsets of the 180 degree refocusing pulse that encode the chemical shift information into the phase of ...

متن کامل

Automatic gradient preemphasis adjustment: a 15-minute journey to improved diffusion-weighted echo-planar imaging.

Image distortion caused by gradient eddy currents is a major problem in the use of diffusion tensor imaging (DTI), as using the uncorrected images for calculation of apparent diffusion coefficient (ADC) and diffusion anisotropy will result in areas of artificially increased anisotropy and ADC at the edge of the images, as well as decreased spatial resolution and accuracy in ADC computations ove...

متن کامل

A Method for Gradient Calibration in Diffusion Weighted Imaging

Introduction. Conventional gradient calibration procedures do not exclude significant bias in the diffusion-weighted (DW) signal during MR experiments. The error, arising from imperfections in the DW gradients, varies among the different gradient directions and exhibits different extent of offsets. We propose a calibration method for DW imaging using a homogeneous water phantom, presuming that ...

متن کامل

Applications of high-resolution echoplanar spectroscopic imaging for structural imaging.

Echoplanar spectroscopic imaging (EPSI) was introduced as a fast alternative for spectroscopic imaging and has been recently implemented on clinical scanners. With further advances in gradient hardware and processing strategies, EPSI can be used to obtain spectroscopic images whose spatial resolution parallels that of conventional anatomic images within clinically acceptable acquisition time. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2000

ISSN: 0740-3194,1522-2594

DOI: 10.1002/1522-2594(200010)44:4<616::aid-mrm16>3.3.co;2-k