Gradient-echo-based 3D submillisecond echo time pulmonary MR imaging: a preliminary usability study on clinical and preclinical MR scanners
نویسندگان
چکیده
منابع مشابه
MR lesion enhancement: spin-echo versus gradient-echo.
We read with interest the two recent articles (1, 2) concerning the comparison of lesion enhancement between spin-echo and gradient-echo magnetic resonance scans. Although they both conclude that minimally enhancing lesions may be missed by a gradient-echo technique, one paper (1) seems to overstate dramatically the theoretical reasons for the clinically observed difference. The authors demonst...
متن کاملGRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.
A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical w...
متن کاملGradient echo (GRASS) MR imaging in cervical radiculopathy.
Limited flip angle (LFA), gradient echo imaging was performed in 130 patients for evaluation of cervical radicular complaints. The LFA study was compared with myelography, CT myelography, and surgical results. Image quality was considered good or excellent for 128 patients. The use of a 10 degrees flip angle with a TR of 75 msec and TE of 12.3 msec consistently provided good contrast and signal...
متن کاملGradient recalled echo MR imaging of the jugular foramen.
Axial T1-weighted spin-echo MR images have not proved to be effective in identifying normal structures in the jugular foramen. By correlating cryomicrotomic sections and axial T1-weighted gradient recalled echo images, we identified the neural and vascular contents of the jugular foramen. Further work with gradient recalled echo images is needed to determine the signal characteristics of jugula...
متن کاملGradient-Echo Imaging Considerations for Hyperpolarized 129Xe MR
Magnetic-resonance imaging using the novel MR signal (26% Xe), which was contained in a 25 cm cylindrical glass cell (2 cm diameter, 7.5 cm length) , at 3 atm, along source provided by hyperpolarized noble gases Xe and He may prove to be an important new diagnostic technique with 3 atm N2 buffer gas and a small quantity of solid Rb. Xe was hyperpolarized in the fringe field of a 1.5 T superfor ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The British Journal of Radiology
سال: 2018
ISSN: 0007-1285,1748-880X
DOI: 10.1259/bjr.20170796