Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit
نویسندگان
چکیده
منابع مشابه
Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit
OBJECTIVE To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. METHODS A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of children from 0 to 15 years old. In a subsequent study, 195 radiographs without gonad shielding w...
متن کاملGonad Shielding during Pelvic Radiography: A Systematic Review and Meta-analysis.
BACKGROUND Gonad shielding has been extensively advocated during pelvic radiography at or below reproductive ages. The popular practice of gonad shielding is placement of a lead shield in the midline of the pelvis. The aim of this study was to address the prevalence of gonad shielding and find out whether the current practice of gonad shielding can be considered as an effective method to reduce...
متن کاملEvaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray
Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...
متن کاملGonad Protection During Paediatric Abdomen and Pelvic X-Ray Examinations
Background: Evidence suggests that children are more susceptible to radiation risks or hazards. In particular, their gonads are more sensitive to the effects of radiation, especially at or below reproductive age. Protecting the gonads of children and adults is of particular importance to the imaging. Aim: To investigate level of the use of gonad protection during paediatric abdomen and pelvic X...
متن کاملOvarian Shielding during Pelvis Radiography: Risk Versus Benefit
Radiography of the pelvis is one of the most common and more frequent radiographic examinations ordered, especially in children [1]. It is estimated that annually a million pelvic radiographs were documented in the UK [2] with frequency of 39 per 1000 of population [3]. Since the 1950s, much focus has been placed on pelvis x-ray examination due to it is associated with direct gonad irradiation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Insights into Imaging
سال: 2011
ISSN: 1869-4101