Glycolide Copolymer Staple-Line Reinforcement Reduces Staple Site Bleeding During Laparoscopic Gastric Bypass
نویسندگان
چکیده
منابع مشابه
Glycolide copolymer staple-line reinforcement reduces staple site bleeding during laparoscopic gastric bypass: a prospective randomized trial.
HYPOTHESIS The use of staple-line reinforcement sleeves during laparoscopic gastric bypass reduces staple-line bleeding, which may translate into a reduction in the rate of gastrointestinal hemorrhage. DESIGN Prospective randomized trial. SETTING University hospital. PATIENTS AND INTERVENTIONS Thirty-four patients undergoing laparoscopic gastric bypass were randomly assigned to receive ei...
متن کاملErratum to: Buttressing the Staple Line: A Randomized Comparison Between Staple-Line Reinforcement Versus No Reinforcement During Sleeve Gastrectomy
Bariatric surgery is recommended for Indian patients with body mass index (BMI) >32.5 kg/m(2) with at least one comorbidity and >37.5 kg/m(2) without a comorbidity. In laparoscopic sleeve gastrectomy, bleeding and leakage from the staple line are common post-operative events. Peri-Strips Dry® with Veritas® (PSD-V) is used in staple-line reinforcement. This was a single-investigator, multicenter...
متن کاملLaparoscopic reinforcement suture on staple-line of duodenal stump using barbed suture during laparoscopic gastrectomy for gastric cancer
Purpose Duodenal stump fistula (DSF) is a serious complication after gastrectomy for gastric cancer. Although risk evaluation and management of DSF were presented by some investigators, there was no technical attempt has been made to prevent DSF during laparoscopic gastrectomy until now. Methods Consecutive 99 patients were enrolled from April 2014 to February 2016 in 2 institutes. All patien...
متن کاملShorter circular staple is height associated with lower anastomotic stricture rate in laparoscopic gastric bypass.
BACKGROUND Anastomotic stenosis, leak, and hemorrhage are common stapler-related complications of laparoscopic Roux-en-Y gastric bypass. In May 2007, we transitioned from a 25-mm diameter, 4.8-mm-height circular stapler to a 25-mm, 3.5-mm-height circular stapler. We hypothesized that the staple height would be associated with a decreased incidence of perioperative complications. METHODS The r...
متن کاملComparison of laparoscopic sleeve gastrectomy leak rates in four staple-line reinforcement options: a systematic review.
OBJECTIVE The study compared laparoscopic sleeve gastrectomy (LSG) staple-line leak rates of 4 prevalent surgical options: no reinforcement, oversewing, nonabsorbable bovine pericardial strips (BPS), and absorbable polymer membrane (APM). BACKGROUND LSG is a multipurpose bariatric/metabolic procedure with effectiveness proven through the intermediate term. Staple-line leak is a severe complic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Archives of Surgery
سال: 2005
ISSN: 0004-0010
DOI: 10.1001/archsurg.140.8.773