Glucose?based carbon electrode for trace?level detection of acetaminophen
نویسندگان
چکیده
A highly sensitive electrochemical method for trace-level detection of acetaminophen (AMP) was employed using glucose-based carbon electrode (Gu/CPE) by cyclic voltammetry (CV) and differential pulse (DPV). Electrochemical properties AMP were well suited in 0.2 M phosphate buffer solution (PBS) pH 7.0 peak intensity at the Gu/CPE enhanced compared to bare paste electrode. Furthermore, different parameters, such as electrolyte, scan rate, accumulation time effects, investigated CV. The redox reaction quasi-reversible controlled a diffusion process with two protons electrons. As per DPV technique, lower limit (LOD) 3.72 × 10–8 over wide linearity range (0.6-9.0 µM) observed. excipient study demonstrates selectivity toward AMP. utilized quantify clinical pharmaceutical samples.
منابع مشابه
Electropolymerization of 4-aminobenzoic acid containing nano-Au deposited on carbon paste electrode for determination of acetaminophen
The conducting polymer films have been widely applied in the field of electrochemistry owing to their goodstability, permselectivity, unique physical and chemical properties. A novel nano-Au/poly (4-aminobenzoicacid) (PABA) film modified carbon paste electrode was fabricated for sensitive detection of acetaminophenin this paper. The PABA film and nano-Au/PABA film were characterized by scanning...
متن کاملDevelopment of Carbon Paste Electrode/EDTA/Polymer Sensor for Heavy Metals Detection
The method used to immobilize the polymer on the Disodium ethylenediamine tetraacetate (EDTA) modified carbon paste electrode (CPE/EDTA) has proved its effectiveness for the detection and chelation of heavy metals in aqueous solution. Its complex formation with Pb(II) was examined by square wave voltammetry and cyclic voltammetry. CPE/EDTA electrodes are predisposed to the phenomenon of dissolu...
متن کاملSynergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...
متن کاملDevelopment of glassy carbon electrode modified with ruthenium red-multiwalled carbon nanotubes for simultaneous determination of epinephrine and acetaminophen.
A glassy carbon electrode modified with ruthenium red and functionalized multi-walled carbon nanotube has been developed. The electrochemical response characteristics of the modified electrode toward epinephrine (EP) and acetaminophen (AC) was investigated by differential pulse voltammetry (DPV). Linear calibration plots were obtained over the range of 0.3 - 333.3 μM for both EP and AC with sen...
متن کاملislanding detection methods for microgrids
امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrochemical science advances
سال: 2021
ISSN: ['2698-5977']
DOI: https://doi.org/10.1002/elsa.202100117