Glucose Oxidase-Coated ZnO Nanowires for Glucose Sensor Applications

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glucose sensor based on glucose oxidase immobilized by zirconium phosphate.

Amperometric glucose sensors were fabricated using glucose oxidase (GOx) entrapped in zirconium hydrogenphosphate (ZrP), and their performance was evaluated. Reportedly, alpha-ZrP is one of the candidates that are expected to improve the stability of enzymes immobilized on solid surfaces. We intercalated GOxs into ZrP (GOx/ZrP), cast the GOx/ZrP suspension in polyvinylalcohol on a platinum elec...

متن کامل

Vertically Aligned Pd Nanowires for Glucose Oxidase Bioanode

A bioanode for glucose based biofuel cell have been fabricated by combining glucose oxidase and highly ordered Palladium (Pd) nanowire array electrode. The Pd nanowires were 5.57 μm in length and 64.28 nm in diameter. The hydrogel composite modified Pd nanowire array bioanodes were characterized with cyclic voltammetry in the presence of different scan rates and different substrate concentratio...

متن کامل

Removal of Malachite Green by Using Immobilized Glucose Oxidase Onto Silica Nanostructure-Coated Silver Metal-Foam

Enzymes Immobilization onto different types of the substrate could be helpful in various applicationsof biomedical devices and biosensors. Enzyme activity and stability could be affected by support andmethod of immobilization. In this study, the silver metal foam was successfully synthesized by thesoft-shell method and then was coated with silica. Then, glucose oxidase (GOx) immobilized on nonc...

متن کامل

Functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose.

In this article, we report a functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose. To adjust the sensor for intracellular glucose measurements, we grew hexagonal ZnO nanorods on the tip of a silver-covered borosilicate glass capillary (0.7 microm diameter) and coated them with the enzyme glucose oxidase. The enzyme-coated ZnO nanorods exhibited a glucose-d...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Korean Journal of Materials Research

سال: 2008

ISSN: 1225-0562

DOI: 10.3740/mrsk.2008.18.12.669