منابع مشابه
Glaucoma drainage devices; past, present, and future.
Glaucoma filtration surgery (GFS) has been shown to be more eVective at preventing disease progression than other primary treatment modalities in open angle glaucoma. 2 If it were possible to avoid complications associated with poor flow control, primary GFS would probably be offered more widely. Trabeculectomy, the procedure of choice in conventional GFS, has remained essentially unchanged for...
متن کاملComparison of different biomaterials for glaucoma drainage devices.
OBJECTIVES To compare the inflammatory reaction associated with the insertion of silicone and polypropylene endplates and endplates made of a new biocompatible polymer, Vivathane, in the rabbit subconjunctival space. METHODS Similar-sized endplates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand...
متن کاملArtificial drainage devices for glaucoma surgery: an overview.
Artificial drainage devices (ADD) create an alternative pathway for aqueous drainage from the anterior chamber of an eye through a tube to the subconjunctival bleb connected to an equatorial plate under the conjunctiva. The ADDs, both valved and non-valved, are available for end stage or refractory glaucoma. Currently, some of these devices, particularly the Express shunt, are recommended for t...
متن کاملComparison of different biomaterials for glaucoma drainage devices: part 2.
BACKGROUND Inflammation associated with biomaterials may contribute to the failure of glaucoma drainage devices. OBJECTIVE To compare the inflammatory reaction associated with the insertion of Krupin silicone, Molteno polypropylene, and Acrosof end plates in the subconjunctival space of rabbits. METHODS Similar-sized glaucoma end plates made of 3 different biomaterials were sutured to the s...
متن کاملValved Glaucoma Drainage Devices in Pediatric Glaucoma: Retrospective Long-term Outcomes.
IMPORTANCE Relatively little data exist about the long-term outcomes of an initial glaucoma drainage device (GDD) and subsequent GDDs implanted in pediatric patients with glaucoma. OBJECTIVE To determine the long-term outcomes of the first and second GDDs and risk factors in pediatric glaucoma. DESIGN, SETTING, AND PARTICIPANTS Retrospective review of 119 eyes of 89 patients younger than 18...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Ophthalmology and Research
سال: 2013
ISSN: 2320-3897