Germanium orthogonal strip detectors with amorphous-semiconductor contacts

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Germanium Orthogonal Strip Detectors with Amorphous-Semiconductor Contacts

Germanium orthogonal strip detectors have been produced using amorphous-semiconductor contacts. The amorphoussemiconductor contact fabrication process is relatively simple, and it is capable of producing fine-pitched electrode structures. The bipolar blocking behavior of the amorphoussemiconductor contact permits its use on both sides of a detector, replacing conventional B ion implanted and Li...

متن کامل

Development of Germanium Strip Detectors for Environmental Remediation1

We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array consists of four detectors, 5 x 5 x 1 cm each with 25 strips on each side. The detectors are daisy-chained to hybrid preamplifiers to reduce the number of channels of electronics. Good spectroscopy and imaging are achieved. We also present r...

متن کامل

Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy

Gamma-ray imaging with position-sensitive germanium detectors offers the advantages of excellent energy resolution, high detection efficiency, and potentially good spatial resolution. The development of the amorphous-semiconductor electrical contact technology for germanium detectors has simplified the production of these position-sensitive detectors and has made possible the use of unique dete...

متن کامل

New Contact Development for Si(Li) Orthogonal-Strip Detectors

At present, the contacts generally used for lithium-drifted silicon detectors consist of a diffused lithium layer (n-type) and a gold surface barrier (p-type). These contacts work well for unsegmented detectors. However, they both have disadvantages if used for segmented detectors. For this reason, we are developing new types of contacts that will be more robust and easier to segment. To replac...

متن کامل

Gamma Spectroscopy with Germanium Detectors

The MAJORANA collaboration[1] aims to detect neutrino-less double beta decay (0νββ) in Ge, using an array of germanium p-type point contact detectors. An important factor in this effort is the minimization of backgrounds from any hardware which is needed to operate the detectors. In order to best understand and minimize this background, one must analyze the gamma spectrum from these pieces of h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Nuclear Science

سال: 2000

ISSN: 0018-9499,1558-1578

DOI: 10.1109/23.872978