Geometric calibration for a dual tube/detector micro-CT system

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT

The quality of Computed Tomography (CT) images crucially depends on the precise knowledge of the scanner geometry. Therefore, it is necessary to estimate and calibrate the misalignments before image acquisition. In this paper, a Two-Piece-Ball (TPB) phantom is used to estimate a set of parameters that describe the geometry of a cone-beam CT system. Only multiple projections of the TPB phantom a...

متن کامل

A geometrical calibration method for the PIXSCAN micro-CT scanner

Reconstruction in Cone-Beam Tomography can suffer from artifacts due to geometrical misalignments of the source-detector system. They can be avoided by a complete and precise description of the system. We present a high precision method for the geometric calibration for the PIXSCAN, a small animal X-ray CT scanner demonstrator based on hybrid pixel detectors (XPAD2). The specificities of the XP...

متن کامل

GECARO: A System for the GEometric CAlibration of RObots

This paper presents a software package for the simulation and the practical calibration of the geometric parameters of robots. This system which is called GECARO, GEometric CAlibration of RObots, contains a large variety of methods to identify the geometric parameters of robots. GECARO is running on PC computers and developed using MATLAB; any general serial robot can be treated directly. The i...

متن کامل

Optimization of scanner parameters for dual energy micro-CT

Two materials of different composition can have very similar grey values in an X-ray Computed Tomography (CT). This is because X-ray CT uses polychromatic sources in combination with energy-integrating detectors and the materials have a mass attenuation coefficient that is dependent on composition and photon energy. A distinction between different materials with similar grey values can be made ...

متن کامل

Dual-Energy CT for the Musculoskeletal System.

The principal advantages of dual-energy computed tomography (CT) over conventional CT in the musculoskeletal setting relate to the additional information provided regarding tissue composition, artifact reduction, and image optimization. This article discusses the manifestations of these in clinical practice-urate and bone marrow edema detection, metal artifact reduction, and tendon analysis, wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2008

ISSN: 0094-2405

DOI: 10.1118/1.2900000