GENERALIZED FRYZE CONTROL STRATEGY FOR SHUNT AND SERIES ACTIVE POWER FILTER
نویسندگان
چکیده
منابع مشابه
Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملA shunt active power filter control for unbalanced conditions
This paper first presents a simple control technique for active filters to compensate current harmonics and reactive power of nonlinear loads. This method is usable for both single –phase and three –phase systems. Then a new method for load balancing and reactive power compensation for unbalanced sinusoidal load currents is presented. Finally by combination of two methods an active filter contr...
متن کاملA Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter
The three-phase three-wire neutral-point-clamped shunt active power filter (NPC-SAPF), which most adopts classical closed-loop feedback control methods such as proportional-integral (PI), proportional-resonant (PR) and repetitive control, can only output 1st–25th harmonic currents with 10–20 kHz switching frequency. The reason for this is that the controller design must make a compromise betwee...
متن کاملControl Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements
The active power filter has been proved to be an effective method to mitigate harmonic currents generated by nonlinear loads as well as to compensate reactive power. The methods of harmonic current detection play a crucial part in the performance of active power filter (APF). This paper presents a new control strategy in which two shunt active power filter configurations are developed in order ...
متن کاملShunt Active Filter for Power Quality Improvement
This paper describes the development of a low cost shunt active power filter with digital control, which allows dynamic power factor correction and both harmonics and zero-sequence current compensation. The active filter controller is based on the instantaneous power theory (p-q theory) and was implemented using a standard 16 bits microcontroller. The p-q theory is introduced followed by the pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Research in Engineering and Technology
سال: 2014
ISSN: 2321-7308,2319-1163
DOI: 10.15623/ijret.2014.0304104