Gated-SPECT Functional Assessment in Overweight and Obese Patients

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

assessment of correlation of left ventricular diastolic functional indices between gated myocardial perfusion spect and echocardiography

conclusions in this study there is no correlation between the main lv diastolic indices derived by spect and echocardiography, may be due to the main changes in the last version of guidline for assessment of lv diastolic function by echocardiography. results the population study consisted of 19 male and 30 female with the average age of 58.2 years.there is a mild negative correlation between pf...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI

Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Diseases & Diagnosis

سال: 2015

ISSN: 2329-9517

DOI: 10.4172/2329-9517.1000226