GAS-TO-WALL ABSORBED DOSE CONVERSION FACTORS FOR NEUTRON ENERGIES OF 25 TO 250 MeV
نویسندگان
چکیده
منابع مشابه
Tritons at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.
Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to tritons ((3)H(+)) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Coefficients were calculated using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder™ 1.3 anthropomo...
متن کاملComments on 'Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations'.
Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft t...
متن کاملResponse functions for computing absorbed dose to skeletal tissues from neutron irradiation.
Spongiosa in the adult human skeleton consists of three tissues-active marrow (AM), inactive marrow (IM) and trabecularized mineral bone (TB). AM is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM(50)), defined as all tissues lying within the first 50 µm of the bone surfaces, i...
متن کاملa case study of energy absorption buildup factors in some human bones for gamma energies 30 kev to 1.5 mev
human body consists of some tissues among which bone is one of the important living and growing tissue . in this research, energy absorption buildup factor (eabf) values of 27 types of bone have been computed for photon energy 0.03 to 1.5 mev up to 40 mean free path (40mfp) penetration depths. the inner bone tissue, spongiosa and male sternum had the largest values of eabf in low photon energie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atomic Data and Nuclear Data Tables
سال: 1997
ISSN: 0092-640X
DOI: 10.1006/adnd.1997.0733