Gas holdup in the bubble column with cocurrent and countercurrent gas-liquid flow.
نویسندگان
چکیده
منابع مشابه
Gas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملLarge Eddy Simulation of the Gas-Liquid Flow in a Square Cross-sectioned Bubble Column
Column N.G. Deen, T. Solberg and B.H. Hjertager Chem. Eng. Lab., Aalborg Univ. Esbjerg; Niels Bohrs Vej 8; DK-6700 Esbjerg; Denmark Abstract In this work the use of large eddy simulations (LES) in numerical simulations of the gas-liquid flow in bubble columns is studied. The Euler-Euler approach is used to describe the equations of motion of the two-phase flow. It is found that, when the drag, ...
متن کاملGas-liquid Flow in a Rectangular Partially Aerated Bubble Column: Combined Effect of Aspect Ratio and Superficial Gas Velocity
Bubble columns are multiphase equipments used to bring into contact gas and liquid phases. Gas, that constitutes the dispersed phase, is distributed at the bottom of the column and rises as bubbles through the liquid that constitutes the continuous phase. They are frequently used in the industry although the partial knowledge of the fluid dynamics of the gas-liquid flow have hindered a complete...
متن کاملAsymptotic Analysis of Binary Gas Mixture Separation by Nanometric Tubular Ceramic Membranes: Cocurrent and Countercurrent Flow Patterns
Analytical gas-permeation models for predicting the separation process across membranes (exit compositions and area requirement) constitutes an important and necessary step in understanding the overall performance of membrane modules. But, the exact (numerical) solution methods suffer from the complexity of the solution. Therefore, solutions of nonlinear ordinary differential equations th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
سال: 1981
ISSN: 0021-9592,1881-1299