Gas Holdup and Average Rising Velocity of Bubble Swarms
نویسندگان
چکیده
منابع مشابه
Eulerian simulation of bubble columns reactors and effect of various parameters on the gas holdup
Gas holdup and bubble size are important parameters for simulation and designing in bubble column reactors. Because based on these parameters, the available gas-liquid interfacial area is defined for mass transfer. In this paper, the results of applying magnetic fields on the velocity field and volume fraction of gas holdup are reported. Hydrodynamics of the bubble column in the reactors is inv...
متن کاملNumerical Study of a Gas Bubble Rising Through Stagnant Fluid
It is well known that the environment degradation has come along the time positioning as one of the main problems from modern world. Among several questions of the environmental interest the methane bubble rise in the lakes can be emphasized, from the anoxic sediment in the bottom of lake until water interface atmosphere. In particular, the present academic work has come to treat mathematic mod...
متن کاملGas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Gas Holdup Behavior in Nylon Fiber Suspensions
The gas holdup behavior in a nylon fiber suspension with various fiber lengths (L = 2, 3, and 6 mm) is investigated. Experiments are performed over a range of superficial gas velocities (Ug≤ 18 cm/s) and a range of fiber mass fractions (0 ≤ C ≤ 1.8%) in a 15.24-cm-diameter semibatch bubble column. Day-to-day variations in the gas holdup create difficulties in interpreting the effect of the fibe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Tetsu-to-Hagane
سال: 1978
ISSN: 0021-1575,1883-2954
DOI: 10.2355/tetsutohagane1955.64.12_1714