Gas Chromatographic Analysis of Automobile Gasoline and Lighter Gas Using Phenyl-Modified Aleppo Bentonite
نویسندگان
چکیده
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
[Burns with lighter gas].
Attention is drawn to a particularly dangerous party activity. Balloons filled with lighter gas so as to float are used for party decorations. A case of hand burn caused by accidentally lighting such a balloon with a cigarette is reported. The method is strongly advised against, it is a much better idea to use helium for such purposes.
متن کاملGas chromatographic analysis of conjugated linoleic acids
The aim was to determine the conjugated linoleic acids in beef with GC-FID. Perfect separation of all of the isomers cannot be achieved, though conjugated linoleic acid isomers proved to be separable from the other fatty acids that are present in beef in a significant amount related to conjugated linoleic acids. Lipid-extraction was carried out with n-hexane/i-propanol, giving 6.8 percent highe...
متن کاملSPECTROPHOTOMETRIC AND GAS CHROMATOGRAPHIC METHODS FOR DETECTION AND ASSAY OF MUSTARD GAS
A colorimetric method for detection and assay of mustard gas in urine after addition of thymolphthalein is reported. The detection limit was 80 ng/ml of llrine. Mustard gas could also be detected in urine after extraction with gas chromatography using FID detector. The detection limit was 10 ng/ml. In addition, thiodiglycol, a metabolite of mustard gas, could be converted to mustard with ...
متن کاملGas-liquid chromatographic analysis of urinary steroids.
A method for gas-liquid chromatographic separation and quantitation of urinary steroid metabolites is described. A normal reference range has been established and classic examples of urinary steroid profiles of the major steroid disorders are given.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Asian Journal of Chemistry
سال: 2014
ISSN: 0970-7077,0975-427X
DOI: 10.14233/ajchem.2014.15750