Gamma spectrometry in the ITWG CMX-4 exercise

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma spectrometry in the ITWG CMX-4 exercise

Low enriched uranium samples of unknown origin were analyzed by 16 laboratories in the context of a Collaborative Materials Exercise (CMX), organized by the Nuclear Forensics International Technical Working Group (ITWG). The purpose was to compare and prioritize nuclear forensic methods and techniques, and to evaluate attribution capabilities among participants. This paper gives a snapshot of t...

متن کامل

Producing 65Zn and 60Co gamma sources for energy and efficiency calibration of gamma spectrometry systems

Precise calibration of energy and efficiency of gamma spectrometry systems for different geometries is very important. In most cases, preparation of these sources for educational and research centers  is very difficult due to high costs and lack of access to the reactor. The purpose of this paper is to explain the procedure for production of calibration sources 65Zn and 60Co using instrumental ...

متن کامل

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Optimization of measurement counting time in Gamma-ray spectrometry of soil samples

The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...

متن کامل

INF/IL-4 increases after the low doses of gamma radiation in BALB/c spleen lymphocytes

Introduction: The effects of the low dose of ionizing radiation are not thoroughly evident due to an unavoidable increase of occupational exposure and the widespread application of ionizing radiation in medical and industrial fields. The aim of this study was to investigate immune system responses following the low doses of ionizing radiation. Materia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Radioanalytical and Nuclear Chemistry

سال: 2018

ISSN: 0236-5731,1588-2780

DOI: 10.1007/s10967-017-5667-2