GAMMA SCANNING TECHNIQUE FOR INVESTIGATING DE-ETHANIZER COLUMN: ON FIELD EXPERIMENTAL AT NGL PLANT
نویسندگان
چکیده
منابع مشابه
Scanning hall probe microscopy technique for investigation of magnetic properties
Scanning Hall Probe Microscopy (SHPM) is a scanning probe microscopy technique developed to observe and image magnetic fields locally. This method is based on application of the Hall Effect, supplied by a micro hall probe attached to the end of cantilever as a sensor. SHPM provides direct quantitative information on the magnetic state of a material and can also image magnetic induction under a...
متن کاملDistillation Column Troubleshooting with Improved Gamma Scan Technique
Gamma scanning is a nuclear inspection technique used to troubleshoot industrial equipments in refineries and petrochemicals plants around the world. In this technique, a sealed radiation source and detector move along an equipment, and the intensity readouts generate a density profile of the equipment. The simplicity of this technique has made it popular in many countries. In recent decades, m...
متن کاملScanning hall probe microscopy technique for investigation of magnetic properties
Scanning Hall Probe Microscopy (SHPM) is a scanning probe microscopy technique developed to observe and image magnetic fields locally. This method is based on application of the Hall Effect, supplied by a micro hall probe attached to the end of cantilever as a sensor. SHPM provides direct quantitative information on the magnetic state of a material and can also image magnetic induction under a...
متن کاملEvaluating the Reliability of an Accurate Performance in Tray Columns Using Gamma Ray Scanning Technique
The nondestructive techniques are applied to identify important data from the internal process of distillation towers, process towers, pressure vessels and etc. In recent, the gamma-ray scanning techniques as diagnostic tools for scanning of tray columns, packed columns, storage tanks, level measurement and density measurement of containing materials has been used widely. This paper has tried t...
متن کاملDouble -Step -Scanning Technique for Spherical Near-Field Antenna Measurements
Probe-corrected spherical near-field antenna measurements with an arbitrary probe set certain requirements on an applicable scanning technique. The computational complexity of the general high-order probe correction technique for an arbitrary probe, that is based on the scanning, is , where is proportional to the radius of the antenna under test (AUT) minimum sphere in wavelengths. With the pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Forum Nuklir
سال: 2020
ISSN: 2580-9547,1978-8738
DOI: 10.17146/jfn.2019.13.3.5412