Gamma-ray spectroscopy for probing highly radioactive items behind thick shields?
نویسندگان
چکیده
منابع مشابه
Instrumentation for Gamma-Ray Spectroscopy
The subject of ttis chapter is the function and operation of the components of a gamma-ray spectroscopy system. In Chapter 3 it was shown that the output pulse amplitude from most gamma-ray detectors is proportional to the energy deposited by the gamma ray. The pulse-height spectrum from such a detector contains a series of full-energy peaks superimposed on a continuous Compton background. Alth...
متن کاملCdZnTe Gamma Ray Spectrometer for Orbital Gamma Ray Spectroscopy
We present the design and analysis of a new gamma ray spectrometer for planetary science that uses an array of CdZnTe detectors to achieve the detection efficiency needed for orbital measurements. The use of CdZnTe will provide significantly improved pulse height resolution relative to scintillation-based detectors, with commensurate improvement in the accuracy of elemental abundances determine...
متن کاملSimulation of gamma-ray gamma rays by composite shields compared to the lead protection using the MCNPX code
In this study, cobalt 60 with a mean energy of (1.25 Mev) was used as a photonic source to investigate the effect of decreasing gamma-ray intensity by materials and polymer composite using MCNPX code. First, we investigated the effect of thickness and density on the reduction of gamma ray intensity, and then the comparison between the lead protector, tungsten and polymer composite in several th...
متن کاملX-Ray Spectroscopy of Gamma-Ray Bursts
Observational evidence of iron absorption and emission lines in X-ray spectra of Gamma-Ray Bursts is quite compelling. I will briefly review the results, summarize different models and describe the connection with massive progenitors in star-forming regions implied by these results. This link is also supported by measurements of the X-ray absorbing gas in several GRB’s, with column density cons...
متن کاملGamma-Ray Instrument for Polarimetry, Spectroscopy
We present an instrument concept called GIPSI that uses germanium strip detectors in an imaging system to provide narrow line sensitivity < 8:0 10 6 cm 2 s 1 at 100 keV in a 2 week exposure (3 ), and which has a point spread function (spatial resolution) of approximately 20 arc minutes rms. The germanium strip detectors also make an excellent polarimeter by capitalizing on the angular dependenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Radiological Protection
سال: 2018
ISSN: 0952-4746,1361-6498
DOI: 10.1088/1361-6498/aad2e6