Gamma 3 U-Blade lag screws in patients with trochanteric femur fractures: are rotation control lag screws better than others?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Load distribution between cephalic screws in a dual lag screw trochanteric nail

BACKGROUND It has been observed clinically that the Z-effect is a potential cause of failure of an intramedullary nail with two cephalic screws. It describes the migration behavior of the cephalic screws in the femoral head. The primary objective was to examine different cephalic screw configurations and test the load distribution between them as a function of their relative placement and their...

متن کامل

Multifragmentary Tibial Pilon Fractures: Midterm Results After Osteosynthesis with External Fixation and Multiple Lag Screws

Osteosynthesis of intraarticular tibial pilon fractures is preferably achieved using locking plates via a minimally invasive technique. If combined with severe soft tissue damage there is a high risk of wound-healing deficits after plate osteosynthesis. Thus our aim was to find an alternative method of treatment for those cases with combined soft tissue injuries.We report on five cases with com...

متن کامل

Far cortical locking screws in distal femur fractures.

Distal femur fractures routinely heal by secondary bone healing, which relies on interfragmentary motion. Periarticular locking plates are commonly used for fixation in distal femur fractures but are associated with a high nonunion rate, likely due to the stiffness of the constructs. Far cortical locking (FCL) screws are designed to allow micromotion at the near cortex while maintaining purchas...

متن کامل

Blocking screws for the treatment of distal femur fractures.

Intramedullary nailing is one of the most convenient biological options for treating distal femoral fractures. Because the distal medulla of the femur is wider than the middle diaphysis and intramedullary nails cannot completely fill the intramedullary canal, intramedullary nailing of distal femoral fractures can be difficult when trying to obtain adequate reduction. Some different methods exis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Orthopaedic Surgery and Research

سال: 2019

ISSN: 1749-799X

DOI: 10.1186/s13018-019-1427-z