G100S axial flow fan simulation comparison analysis

نویسندگان

چکیده

Abstract This paper conducts a comparative simulation for different structural layout schemes of the new G100S axial flow fan, with motor position and its supporting guide vane as main modification direction, while fan length tongue angle are appropriately adjusted according to position. CFD analysis calculation used compare study performance axial-flow fan. The results show that rear motor, air outlet cone integration, large has greater wind speed, longer injection distance, more uniform distribution field traces, pressure at outlet, faster stability convergence. work will provide technical support designing orthogonal experiments in direction miniaturization lightweight.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing Axial Flow Fan for Flow and Noise

A comprehensive finite element methodology is developed to predict the compressible flow performance of a non-symmetric 7-blade axial flow fan, and to quantify the source strength and sound pressure levels at any location in the system. The acoustic and flow performances of the fan are predicted simultaneously using a computational aero-acoustic technique combining transient flow analysis and n...

متن کامل

Experimental comparison between a counter-rotating axial-flow fan and a conventional rotor-stator stage

Based on the requirement of energy consumption level and weight and dimension restriction, compact axial machines are highly demanded in many industrial fields. The counter-rotating axial-flow fans could be a promising way to achieve these requirements. Because of the reduction of rotational speed and a better homogenization of the flow downstream of the rear rotor, these machines may have very...

متن کامل

Flow Characteristics Impeller Change of an Axial Turbo Fan

In this paper, three dimensional flow characteristic was presented by a revision of an impeller of an axial turbo fan for improving the airflow rate and the static pressure. TO consider an incompressible steady three-dimensional flow, the RANS equations are used as the governing equations, and the standard k-ε turbulence model is chosen. The pitch angles of 44°, 54°, 59°, and 64° are implemente...

متن کامل

Effect of Blade Design Parameters on Air Flow through an Axial Fan

The objective of this paper is the numerical study of the flow through an axial fan and examining the effects of blade design parameters on the performance of the fan. The axial fan is extensively used for cooling of the electronic devices and servers. Simulation of the three-dimensional incompressible turbulent flow was conducted by numerical solution of the (RANS) equations for a model. The S...

متن کامل

Flows in Duct for Axial Fan

Axial flow fan has been used for large amount of flow rate in air handling units of industrial application fields. The fan involves a shrouding duct as flow guidance for uniform flows. Pressure difference between before and ahead of rotating blades causes the flows movements. The case where the flow resistance such as a heat exchanger is located prior to the rotors is typical in-field model for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2022

ISSN: ['1742-6588', '1742-6596']

DOI: https://doi.org/10.1088/1742-6596/2403/1/012039