Fuzzy Reliability Analysis of a Summer Air Conditioning System
نویسندگان
چکیده
منابع مشابه
Air Conditioning System with Fuzzy Logic and Neuro-Fuzzy Algorithm
Fuzzy logic controls and neuro-fuzzy controls are accustomed to increase the performance of air conditioning system. In this paper, we are trying to provide the new design air conditioning system by exploitation two logics, namely fuzzy logic and neuro-fuzzy management. This paper proposes a set of rule and uses 2 inputs specifically temperature and humidness and 4 outputs specifically compress...
متن کاملDesign of a Radiant Panel Cooling System for Summer Air Conditioning System
The main objective of this investigation was to design and investigate a radiant panel cooling system on small scale building type (office) under the central Sudan climatic conditions so as to explore the benefits of radiant cooling systems over conventional air conditioning systems (Variable air volume systems). Transient heat conduction of building (finite difference method) was used to evalu...
متن کاملDevelopment of Neuro Fuzzy Controller Algorithm for Air Conditioning System
The paper presents the neuro-fuzzy controller algorithm for air conditioning system. Neuro-fuzzy control combines the learning capabilities of neural networks and control capabilities of fuzzy logic control. The neurofuzzy controller for air conditioning system takes two inputs from temperature and humidity sensors and controls the compressor speed. The experimental results of the developed sys...
متن کاملA fuzzy approach to reliability analysis
Most of the existing approaches for fuzzy reliability analysis are based on fuzzy probability. The aim of this paper is to describe fuzzy reliability using fuzzy differential equation. The reliability of a system in real world applications is affected by some uncertain parameters. Fuzzy reliability is a way to present the reliability function uncertainly using fuzzy parameters. In the proposed...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Fuzzy Mathematics
سال: 2017
ISSN: 0974-0201,0973-533X
DOI: 10.37622/afm/12.2.2017.319-332