Fuzzy Logic Based Power System Contingency Ranking
نویسندگان
چکیده
منابع مشابه
Fuzzy Approach to Contingency Ranking
The contingencies contribute to overloading of network branches and unsatisfactory voltages, which may lead to problems of stability/voltage collapse. The most important task in security analysis is the problem of identifying the critical contingencies from a large list of credible contingencies and rank them according to their severity. This paper presents fuzzy approach for ranking the contin...
متن کاملCascade fuzzy neural network based voltage contingency screening and ranking
A method based on cascade fuzzy neural network (CFNN) comprising of a filter module and ranking module is proposed for online voltage contingency screening and ranking under known but uncertain loads. A new fuzzy performance index, which combines voltage violations and voltage stability margin following a contingency, is proposed for effective voltage security ranking. All the selected continge...
متن کاملFuzzy Approach to Voltage Collapse based Contingency Ranking
The importance of preventing the voltage collapse is gaining importance due to increase in dependency on the use of electricity. This has compelled the utilities to maintain high system reliability. The evaluation of a power systems ability to withstand dangerous contingencies and to survive to a normal or acceptable operating point is a prerequisite for security analysis. Fast and accurate sec...
متن کاملFuzzy Logic Based Hydro-Electric Power Dam Control System
This research paper presents the construction design of Hydro-Electric Power Dam Control System using Fuzzy Logic. In this design two input parameters: water level and flow rate and two output parameters: release valve control and drain valve control are used. This proposed system uses a simplified algorithmic design approach with wide range of input and output membership functions. The hardwar...
متن کاملA Fuzzy Logic Based Discrete Mode Power System Stabilizer
A Fuzzy Power System Stabiliser (FPSS) design using discrete inputs is presented. The FPSS basically utilises only one measurable plant signal as input, namely, the generator speed. The speed signal is discretised resulting in three inputs to the FPSS. A simplified power system represented by a single generator transmitting power to the infinite bus is considered for investigations. The system ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Intelligent Systems and Applications
سال: 2013
ISSN: 2074-904X,2074-9058
DOI: 10.5815/ijisa.2013.03.01