Fuzzy and Matlab/Simulink Modelling of the Air Compression Refrigeration Cycle
نویسندگان
چکیده
The coefficient of performance (COP) for a gas refrigeration cycle was estimated using Matlab/Simulink and fuzzy logic. A model the developed, output compared to theoretical data. Additionally, logic used estimate COP arbitrary low- high-pressure levels. Simulation results were develop multi-input-multi-output (MIMO) Takagi-Sugeno-Kang (TSK)-based model. Both MIMO found be very well correlated with results, an error less than 2 %. These demonstrate effectiveness analyse cycles suggest that this approach can extended other thermodynamic cycles.
منابع مشابه
Experimental investigation on the effect of phase change materils (PCM) in solar compression refrigeration cycle efficiency
Saving energy is one of the most important challenges of todaychr('39')s world. Reducing electrical energy consumption in compressed air systems is one of the essential requirements for designing these systems. When using domestic air conditioners (dual air conditioners) in very hot areas (Khuzestan) their performance decreases and electric current consumption increases. Therefore, the use of n...
متن کاملDynamical modeling and thermo-economic optimization of a cold room assisted vapor-compression refrigeration cycle
A cold room assisted vapor-compression refrigeration cycle is dynamically modeled in a year and optimized. Total annual cost (TACO) and coefficient of performance (COP) are selected as two objective functions. Both cold room and refrigeration cycle parameters are considered as design variables. Moreover, three working fluids included R22, R134a and R407c are examined. The optimum Pareto front r...
متن کاملPerformance of High Pressure Air Cycle in Comparison With Synthetic and Natural Vapor Compression Refrigeration Cycles
Concerning the use of HFCs as substitutes for CFCs and HCFCs a major concern in applications with remarkable leakages of refrigerant is its contribution to global warming. Therefore, the attention has been drawn to the use of natural working fluids, like carbon dioxide, hydrocarbons, water and air. Air had been already used in the range of air conditioning technology. Air as refrigerants is sta...
متن کاملThe energy and exergy analysis of a novel cogeneration organic Rankine power and two-stage compression refrigeration cycle
The energy crisis in recent years has led to the use of thermodynamic cycles that work based on renewable energies. Low-temperature cycles—such as organic cycles—are suitable strategies for the application of renewable energies. The present study proposes a novel cycle through the integration of a two-stage compression refrigeration cycle with a combined Rankine power and ejector refrigerat...
متن کاملMulti-objective optimization of compression refrigeration cycle of Unit 132 South Pars refineries
The purpose of this paper is multi-objective optimization of refrigeration cycle by optimization of all components of the cycle contains heat exchangers, air condenser, evaporator and super-heater. Studied refrigeration cycle is compression refrigeration cycle of unit 132 Third refineries in south pars that provide chilled water for cooling refinery equipment's. Cycle will be performed by t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Strojniški vestnik
سال: 2023
ISSN: ['2536-3948', '0039-2480']
DOI: https://doi.org/10.5545/sv-jme.2023.597