FUNDAMENTAL STUDY OF STRUCTURAL CONTROL CAPACITY OF MAXWELL TYPE SEMI-ACTIVE DAMPER
نویسندگان
چکیده
منابع مشابه
Upgrading the Seismic Capacity of Pile-Supported Wharfs Using Semi-Active Liquid Column Gas Damper
One of the most important structures in the ports is the wharf. The most common one is the pile-supported wharf. This type of wharf is consisted of a number of piles and one deck which placed on the piles. In addition to the conventional loads that this structure should withstand, in seismic areas, pile-supported wharfs should have the necessary capacity and strength against seismic excitations...
متن کاملSemi-active control of seat suspension with MR damper
The vibration control of a seat suspension system with magnetorheological (MR) damper is investigated in this study. Firstly, a dynamical model of the seat suspension system with parameter uncertainties (such as mass, stiffness, damping) and actuator saturation is established. Secondly, based on Lyapunov functional theory and considering constraint conditions for damping force, the semi-active ...
متن کاملSemi-active H∞/LPV control for an industrial hydraulic damper
In this paper, a new control strategy is developed to improve comfort and roadholding of a ground vehicle equipped with an industrial damper. This damper can be controlled by means of a small servomechanism which adjusts the damping rate. The main controller is a linear parameter varying (LPV ) static state-feedback controller synthesized in the H∞/LPV framework to compute the required damping ...
متن کاملprevalence of atopic dermatitis in children with type 1 diabetes mellitus in southeastern of iran (kerman province): a case-control study
چکیده ندارد.
15 صفحه اولStudy and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2003
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.68.63_1