Functionalized microneedles for continuous glucose monitoring
نویسندگان
چکیده
منابع مشابه
Microfabricated Microdialysis Microneedles for Continuous Medical Monitoring
(1) Berkeley Sensor and Actuator Center – University of California, Berkeley. 497 Cory Hall, Berkeley, CA 94720-1774 (2) Department of Bioengineering – University of California, Berkeley. 459 Evans Hall, Berkeley, CA 94720-1762 (3) Department of Mechanical Engineering – University of California, Berkeley. Berkeley, CA 94720-1740, USA -Tel +1 510 642 9360, Fax +1 510 643 6637, Email liepmann@me....
متن کاملContinuous glucose monitoring system for congenital hyperinsulinemia.
Blood glucose monitoring is a way of testing the concentration of glucose in the blood. The most recent advance is the development of continuous glucose monitoring system (CGMS) which gives 24 hour trend of blood sugar levels thus helping both the patient and the physician in achieving better glycemic control. CGMS in pediatric population is generally used for those on insulin pumps and those w...
متن کاملContinuous glucose monitoring and pumps.
BACKGROUND While multiple daily insulin injections remains the state-of-the-art treatment for type 1 diabetes, continuous subcutaneous insulin infusion (CSII) has become increasingly popular in recent years. Up to 40% of people with type 1 diabetes in younger age groups are now using CSII. Very recently, continuous glucose monitoring (CGM) has been developed. This technology now has proven bene...
متن کاملContinuous Glucose Monitoring in Patients With Type 2 Diabetes Receiving Insulin Injections: Does This Mean Continuous Glucose Monitoring for Everyone?
Receiving Insulin Injections: Does ThisMean Continuous Glucose Monitoring for Everyone? D advances in care over the past 2 decades, nearly half of persons living with type 2 diabetes mellitus (T2DM) have uncontrolled disease and are at high risk for complications (1). New technologies aimed at treatment, including advancements in glucose monitoring, may affect control and reduce hypoglycemia ri...
متن کاملToward a Continuous Intravascular Glucose Monitoring System
Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nano Convergence
سال: 2018
ISSN: 2196-5404
DOI: 10.1186/s40580-018-0161-2