Functional results with aortic ball valve prostheses (Starr-Edwards) followed for two to three years.
نویسندگان
چکیده
منابع مشابه
Functional results with aortic ball valve prostheses (Starr-Edwards) followed for two to three years.
It is now believed that aortic insufficiency and calcific aortic stenosis must be treated with total valve replacement. Until recently this was performed with the aid of prostheses of teflon and similar materials. Even if the short-term results were promising, follow-up studies revealed a high percentage of breakdown of these prostheses (Bjork, Cullhed, and Lodin, 1963; Larson and Kirklin, 1964...
متن کاملFixation of aortic ball valve prosthesis (Starr-Edwards).
The technique of fixation of a ball valve prosthesis in the area of the non-coronary cusp by bringing the sutures from the collar of the prosthesis out through the wall of the aorta and tying them over strips of dacron has been discussed by Starr, Edwards, McCord, and Griswold (1963), and advocated by Effler, Groves, and Favaloro (1964). We have never in our first 100 operated cases seen a leak...
متن کاملBentall procedure 39 years after implantation of a Starr-Edwards Aortic Caged- Ball-Valve Prosthesis
We report a case of a male patient who received an implantation of a Starr-Edwards-caged-ball-valve-prosthesis in 1967. The surgery and postoperative course were without complications and the patient recovered well after the operation. For the next four decades, the patient remained asymptomatic--no restrictions on his lifestyle and without any complications. In 2006, 39 years after the initial...
متن کاملReplacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...
متن کاملValve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thorax
سال: 1967
ISSN: 0040-6376
DOI: 10.1136/thx.22.1.21