FUNCTIONAL OUTCOMES OF DISTAL RADIUS FRACTURES MANAGED WITH 2.7MM VARIABLE ANGLE VOLAR LOCKING COMPRESSION PLATES

نویسندگان

چکیده

Objective: About 15 to 17 % of all fractures presenting emergency department constitutes the distal radius fracture. Intra-articular fracture remains one most challenging be reduced over decades for orthopedic surgeons. Objective is demonstrate functional outcomes 2.7mm variable angle volar locking compression plate using Mayo’s wrist score in fracture.
 Methodology: A Quasi experimental study was conducted Department Orthopedics & Trauma, CMH Rawalpindi from 20th October 2020 19th April 2021. total 120 patients with AO Classification A1 C2 C3, 19 69 years age both genders were included. Outcome Variable Volar Locking Compression Plates calculated. Data entered SPSS version 25. Descriptive analysis done age. Gender and mayo scoring criteria presented as frequencies percentages. To analyze association outcome gender chi-square test applied.
 Results: Mean 40.34 ± 8.01 years. Majority 71 (59.17%) between 40 Out patients, 82 (68.33%) males 38 (31.67%). 51 (42.50%) had excellent outcome, 47 (29.17%) good 13 (10.83%) fair 09 (7.50%) poor outcome.
 Conclusion: The very good.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius volar locking plates: does a variable angle locking system confer a clinical advantage?

This retrospective study compared clinical, radiological and subjective outcomes between patients with a distal radius fracture fixed with a variable angle or fixed angle volar locking plate. Radiological parameters were assessed between initial and final post-operative films. Post-operative clinical range of motion as a proportion of that in the opposite wrist was assessed clinically, and sati...

متن کامل

Are intra-articular distal radius fractures best managed with volar locking plates or bridging external fixation?

Introduction Distal radius fractures are the sixth most commonly occurring fracture. Controversy surrounds the optimal method of fixation with both volar locking plate and bridging external fixation being advocated. This systematic review aims to compare these techniques in the treatment of intra-articular fractures. Materials and methods The electronic databases Medline and EMBASE were searche...

متن کامل

Restoration of teardrop angle (TDA) in distal radius fractures treated with volar locking plates

Distal radius fractures are common fractures of the upper extremity, estimated to account for one-sixth of all fractures seen and treated in emergency rooms.1-3 These fractures are seen in a bimodal age distribution and usually result from a low-energy trauma. Displaced fractures involving the articular surface of the distal radius have the worst prognosis because of the potential for incongrui...

متن کامل

surgical treatment of unstable distal radius fractures with a volar variable-angle locking plate: clinical and radiological outcomes

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

متن کامل

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes

BACKGROUND Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. OBJECTIVES This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. PATIENT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pakistan postgraduate medical institute

سال: 2022

ISSN: ['2710-1924']

DOI: https://doi.org/10.51642/ppmj.v33i03.485