Functional Outcome of Isolated Hoffa Fractures Treated with Cannulated Cancellous Screw
نویسندگان
چکیده
منابع مشابه
Functional Outcome of Isolated Hoffa Fractures Treated with Cannulated Cancellous Screw
Introduction: Isolated Hoffa fracture is an infrequent injury and little research has been done on this subject. The purpose of this study was to evaluate the functional outcome and complications of surgically managed Hoffa fractures with cannulated cancellous screw. Materials and Methods: Between 2011 and 2014, eight isolated Hoffa fractures in seven adult patients with mean age 39.8±11.9 year...
متن کاملCannulated cancellous screw fixation for capitellum fractures in adolescents.
PURPOSE To review the outcome of 9 adolescents treated with 2 to 3 cannulated cancellous screws for type-1 capitellum fractures. METHODS Records of 8 boys and one girl aged 12 to 14 (mean, 14) years with type-1 capitellum fractures were reviewed. The mechanism of injury was a fall on the flexed elbow. No patient had associated injuries or neurovascular compromise. In 2 patients, the fracture ...
متن کاملCannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
Purpose. To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. Methods. 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55o and 63o (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...
متن کاملLetter to the Editor: Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study.
PURPOSE To compare the compressive strength of cannulated versus non-cannulated cancellous screws for undisplaced femoral neck fractures in synthetic bones. METHODS 18 synthetic proximal femurs simulating an AO B1 valgus impacted femoral neck fracture in osteoporotic bone were used. The fracture angles were between 55º and 63º (Pauwels grade 2). Fixation was made using 6.5-mm non-cannulated s...
متن کاملThe functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation
Abstract Background: Unstable Pelvic fracture, a result of high energy antero-posterior compression injury, has been managed based on internal fixation and open reduction. The mode of fixation in Unstable Pelvic fracture has, however, been a subject of controversy and some authors have proposed a need to address the issue of partial breach of the pelvic ring elements in these injuries. This st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Malaysian Orthopaedic Journal
سال: 2017
ISSN: 1985-2533
DOI: 10.5704/moj.1707.016