Functional MRI using regularized parallel imaging acquisition

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional MRI using regularized parallel imaging acquisition.

Parallel MRI techniques reconstruct full-FOV images from undersampled k-space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal-to-noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss ...

متن کامل

High temporal resolution functional MRI using parallel echo volumar imaging.

PURPOSE To combine parallel imaging with 3D single-shot acquisition (echo volumar imaging, EVI) in order to acquire high temporal resolution volumar functional MRI (fMRI) data. MATERIALS AND METHODS An improved EVI sequence was associated with parallel acquisition and field of view reduction in order to acquire a large brain volume in 200 msec. Temporal stability and functional sensitivity we...

متن کامل

Parallel imaging techniques in functional MRI.

Originally developed for increased scanning velocity in cardiac imaging, parallel imaging (PI) techniques have recently also been applied for the reduction of artifacts in single-shot techniques. In functional brain imaging (fMRI) techniques, PI has been used for several purposes. It has been applied to reduce the distortions caused by the length of the echo-planar imaging readout, diminution o...

متن کامل

Echo-Planar Cardiac MRI using Parallel Imaging

Since it’s original proposal by Mansfield et al. in 1977 [1], echo-planar imaging (EPI) has had a key role in the evolution of cardiac MRI. EPI involves the rapid acqusition of k-space data in a raster-like fashion, requiring a fewer number of excitations compared to conventional 2DFT imaging. This is crucial in cardiac imaging as respiratory and cardiac motion places high demands on imaging sp...

متن کامل

Fast Undersampled Functional Magnetic Resonance Imaging Using Nonlinear Regularized Parallel Image Reconstruction

In this article we aim at improving the performance of whole brain functional imaging at very high temporal resolution (100 ms or less). This is achieved by utilizing a nonlinear regularized parallel image reconstruction scheme, where the penalty term of the cost function is set to the L(1)-norm measured in some transform domain. This type of image reconstruction has gained much attention recen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2005

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.20555