Function spaces and optimal currents in impedance tomography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

compactifications and function spaces on weighted semigruops

chapter one is devoted to a moderate discussion on preliminaries, according to our requirements. chapter two which is based on our work in (24) is devoted introducting weighted semigroups (s, w), and studying some famous function spaces on them, especially the relations between go (s, w) and other function speces are invesigated. in fact this chapter is a complement to (32). one of the main fea...

15 صفحه اول

Improved methods to determine optimal currents in electrical impedance tomography

An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are developed. Direct methods to first determine the resistance matrix of a resistivi...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography 613 An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography

A method to produce a desired current pattern in a multiple-source EIT system using voltage sources is presented. Application of current patterns to a body is known to be superior to the application of voltage patterns in terms of high spatial frequency noise suppression, resulting in high accuracy in conductivity and permittivity images. Since current sources are difficult and expensive to bui...

متن کامل

Optimal imaging with adaptive mesh refinement in electrical impedance tomography.

In non-linear electrical impedance tomography the goodness of fit of the trial images is assessed by the well-established statistical chi2 criterion applied to the measured and predicted datasets. Further selection from the range of images that fit the data is effected by imposing an explicit constraint on the form of the image, such as the minimization of the image gradients. In particular, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Inverse and Ill-posed Problems

سال: 2011

ISSN: 0928-0219,1569-3945

DOI: 10.1515/jiip.2011.022