Fully Automated Two-dimensional Capillary Electrophoresis for High Sensitivity Protein Analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully automated two-dimensional capillary electrophoresis for high sensitivity protein analysis.

We report a system for automated protein analysis. In the system, proteins are labeled with the fluorogenic reagent 3-(2-furoyl)quinoline-2-carboxaldehyde, which reacts with lysine residues and creates a highly fluorescent product. These labeled proteins are analyzed by submicellar capillary electrophoresis at pH 7.5 to perform a first dimension separation. Once the first components migrate fro...

متن کامل

A robust, high-sensitivity algorithm for automated detection of proteins in two-dimensional electrophoresis gels

The automated interpretation of two-dimensional gel electrophoresis images used in protein separation and analysis presents a formidable problem in the detection and characterization of ill-defined spatial objects. We describe in this paper a hierarchical algorithm that provides a robust, high-sensitivity solution to this problem, which can be easily adapted to a variety of experimental situati...

متن کامل

A stability indicating capillary electrophoresis method for analysis of buserelin

A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...

متن کامل

Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis.

A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing ...

متن کامل

Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.

CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Molecular & Cellular Proteomics

سال: 2002

ISSN: 1535-9476

DOI: 10.1074/mcp.t100009-mcp200