Fully Automated Two-dimensional Capillary Electrophoresis for High Sensitivity Protein Analysis
نویسندگان
چکیده
منابع مشابه
Fully automated two-dimensional capillary electrophoresis for high sensitivity protein analysis.
We report a system for automated protein analysis. In the system, proteins are labeled with the fluorogenic reagent 3-(2-furoyl)quinoline-2-carboxaldehyde, which reacts with lysine residues and creates a highly fluorescent product. These labeled proteins are analyzed by submicellar capillary electrophoresis at pH 7.5 to perform a first dimension separation. Once the first components migrate fro...
متن کاملA robust, high-sensitivity algorithm for automated detection of proteins in two-dimensional electrophoresis gels
The automated interpretation of two-dimensional gel electrophoresis images used in protein separation and analysis presents a formidable problem in the detection and characterization of ill-defined spatial objects. We describe in this paper a hierarchical algorithm that provides a robust, high-sensitivity solution to this problem, which can be easily adapted to a variety of experimental situati...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملFully integrated PCR-capillary electrophoresis microsystem for DNA analysis.
A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing ...
متن کاملTwo-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection.
CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Molecular & Cellular Proteomics
سال: 2002
ISSN: 1535-9476
DOI: 10.1074/mcp.t100009-mcp200