FULL SCALE SHAKING TABLE TEST OF FLEXIBLE-STIFF MIXED STRUCTURE WITH BRACE-TYPE HYSTERETIC DAMPERS
نویسندگان
چکیده
منابع مشابه
damping of stay cable with passive-on magnetorheological dampers: a full-scale test
damping of a full-scale cable with a pair of passive–on magnetorheological (mr) dampers was tested. a cable of 215.58m long with the first mode frequency of 0.658hz was tensioned horizontally in cable prefabrication factory. two mr dampers were attached to the cable in an angle in the plane perpendicularly to the cable axis in 5m length from the cable anchorage. the applied voltage level was 0v...
متن کاملA Design Methodology for Hysteretic Dampers
This research proposes a design methodology for hysteretic dampers in buildings under high levels of seismic hazard. Developments in structural materials have led to designs that satisfy strength requirements but are often very flexible. This trend, along with increasingly stringent building performance criteria, suggests a philosophy of controlling structural motion as opposed to merely design...
متن کاملDynamic Experiment and Numerical Simulation of a Full Scale Steel Frame with Viscous Dampers
This paper presents a dynamic nonlinear numerical simulation of a 5-story full-scale steel frame structure based on Perform-3D. Flexibility-based fiber element and Maxwell model are adopted for structure member simulation after a post analysis of the shaking table test of a 4-story full-scale steel frame. The author simulates the low cyclic reciprocating load test for the steel members with fib...
متن کاملFull-scale experimental verification of resetable semi-active stiffness dampers
Because of many advantages over other control systems, semi-active control devices have received considerable attention for applications to civil infrastructures. A variety of different semi-active control devices have been studied for applications to buildings and bridges subject to strong winds and earthquakes. Recently, a new semi-active control device, referred to as the resetable semi-acti...
متن کاملTHE SHAKING TABLE CONCENTRATOR: INFLUENCE OF TABLE PARAMETERS ON MANGANESE CONCENTRATION
Abstract: point of view. In this study, a shaking-table was used for concentrating a manganese ore sample from the Ghasem Abadarea in Kerman, Iran. Experiments were designed by using LThe influence of each variable and their interactions on the operation of the device was studied. The variables underinvestigation were: table slope, table frequency, water flowrate, feed rate, and particle size. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2001
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.66.171_1