Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.
A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for his...
متن کاملPolycapillary X-ray optics for microdiffraction
Polycapillary optics, i.e. shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate or focus X-ray beams. X-rays emitted over a large angular range from conventional laboratory-based sources can be transformed into a beam with a small angular divergence or focused onto a small sample or sample area. Convergent beams of X-rays, with co...
متن کاملFull-field transmission x-ray microscopy for bio-imaging.
A full-field hard-x-ray microscope at SSRL has successfully imaged samples of biological and environmental origin at 40 nm resolution. Phase contrast imaging of trabeculae from a female mouse tibia, loaded in vivo to study the effects of weight-bearing on bone structure, revealed a complex network of osteocytes and canaliculi. Imaging of cordgrass roots exposed to mercury revealed nanoparticles...
متن کاملGrid-enhanced X-ray coded aperture microscopy with polycapillary optics
Polycapillary devices focus X-rays by means of multiple reflections of X-rays in arrays of bent glass capillaries. The size of the focal spot (typically 10-100 μm) limits the resolution of scanning, absorption and phase-contrast X-ray imaging using these devices. At the expense of a moderate resolution, polycapillary elements provide high intensity and are frequently used for X-ray micro-imagin...
متن کاملBeam collimation with polycapillary x-ray optics for high contrast high resolution monochromatic imaging.
Monochromatic imaging can provide better contrast and resolution than conventional broadband radiography. In broadband systems, low energy photons do not contribute to the image, but are merely absorbed, while high energy photons produce scattering that degrades the image. By tuning to the optimal energy, one can eliminate undesirable lower and higher energies. Monochromatization is achieved by...