Full circuit calculation for electromagnetic pulse transmission in a high current facility

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Speed Full Swing Current Mode BiCMOS Logical Operators

In this paper the design of a new high-speed current mode BiCMOS logic circuits isproposed. By altering the threshold detector circuit of the conventional current mode logic circuitsand applying the multiple value logic (MVL) approach the number of transistors in basic logicoperators are significantly reduced and hence a reduction of chip area and power dissipation as wellas an increase in spee...

متن کامل

A directional-based branches current method for transmission loss allocation in the pool-based electricity market

This paper proposes a new method for transmission loss allocation. The share of each bus in the transmission line losses is determined using transmission line loss equations with respect to bus-injected currents. Then, it is applied to the total network transmission lines. In the proposed method, comparing with other methods, a solution to remove the negative loss allocation has been introd...

متن کامل

Calculation of Electromagnetic Field inside a Wire Structure in a Pulse Field of Lightning Discharge

Calculation of electric field and potential inside a wire structured object in external pulse electromagnetic field of lightning discharge is presented in this paper. Conductive structure is solved as a receiving antenna using program SPAN [1,2] for an arbitrary antenna configuration, consisting of lineic cylindrical segments, in external electromagnetic field. One simple approximation [3] for ...

متن کامل

A Method for Restraining Electromagnetic Interference of Electricity Meter by Means of Pulse Width Testing Circuit

Abstrac t This paper describes a method for restraining electromagnetic interference received by reference meter clearly not caused by watt-hour meter under test by means of pulse width testing circuit. The method is adopted to resolve the problems often occurred in the type tests of watt-hour meters. During the EMC test of watt-hour meters, the tester can’t confirm the additional error due to ...

متن کامل

Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams

سال: 2014

ISSN: 1098-4402

DOI: 10.1103/physrevstab.17.110401