Front Cover: Number of theoretical plates achievable by a toroidal capillary electrophoresis system
نویسندگان
چکیده
منابع مشابه
Serum protein electrophoresis by CZE 2000 clinical capillary electrophoresis system.
We compared the automated Paragon 2000 clinical capillary zone electrophoresis (CZE) system with two manual methods, agarose electrophoresis (AGE) and cellulose acetate electrophoresis (CAE). Reference intervals in healthy adults were determined for each method. When compared with AGE and CAE, CZE gave substantially higher reference values for the alpha1-globulin fraction. With CZE, within-run ...
متن کاملLarge-volume sample sweeping with a high theoretical plate number using a coupled-capillary in capillary electrophoresis.
A large-volume sample injection (> 5 microL) with an extremely high theoretical plate number (N > 10(7)) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 microm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED ( approximately 2 mW) was used as the fluorescence excitation source. As a result, the theoretica...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملHigh-pressure gel loader for capillary array electrophoresis microchannel plates.
Microfabricated capillary array electrophoresis (microCAE) microchannel plates are the next generation of bioanalytical separation devices. To fully exploit the capabilities of microCAE devices, supporting technology such as robotic sample loading, gel loading, microplate washing, and data analysis must be developed. Here, we describe a device for loading gel into radial capillary array electro...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Separation Science
سال: 2017
ISSN: 1615-9306
DOI: 10.1002/jssc.201770231