Frictional Electrification on Polymeric Flat Surfaces
نویسندگان
چکیده
منابع مشابه
Frictional Electrification on Polymeric Flat Surfaces
The electrostatic charge on nylon, polypropylene (PP), and polytetrafluoroethylene (PTFE) after rubbing against stainless steel and against each other was examined using a newly developed rubbing device with automated features. It is observed that the charge generated on PTFE and PP increases as the contact force increases, while the charge generated on nylon is not affected by the contact forc...
متن کاملFlat polymeric microlens array
A polymer-based flat microlens array is demonstrated. Within each pixel of the array, the polymer presents a circular central-symmetric inhomogeneous orientation. Pixel with such a structure behaves a lens-like character. A suitable amount of liquid crystal mixed in the polymer host can improve not only the lens flexibility but also the lens performance. Moreover, the polymer-based microlens ar...
متن کاملFrictional energy dissipation in contact of nominally flat rough surfaces under harmonically varying loads
If the nominal contact tractions at an interface are everywhere below the Coulomb friction limit throughout a cycle of oscillatory loading, the introduction of surface roughness will generally cause local microslip between the contacting asperities and hence some frictional dissipation. This dissipation is important both as a source of structural damping and as an indicator of potential frettin...
متن کاملCrystallization of calcium sulfate on polymeric surfaces.
Surface crystallization of calcium sulfate dihydrate (gypsum) on a series of polymeric surfaces was studied using a quartz microbalance system. Polyelectrolyte multilayer films (positively and negatively charged surfaces) were formed on the quartz crystal microbalance (QCM) sensors utilizing a layer-by-layer spin-assembly method. The kinetics of gypsum surface crystallization was quantified in ...
متن کاملBiofilm Formation on Polymeric Heat Transfer Surfaces
The biofouling affinity on different polymeric surfaces (PP, PSU, PET, PEEK) in comparison with SS 1.4301 was studied using the model bacterium E.coli K12 DSM 498. A test rig with seven identical chambers allowed investigations at different system conditions (throughputs, inclination of the heat transfer cell, etc.). The biofilm mass deposited on the polymer surfaces was several magnitudes smal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Engineered Fibers and Fabrics
سال: 2013
ISSN: 1558-9250,1558-9250
DOI: 10.1177/155892501300800115