Freestyle Libre Glucose Monitoring System

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus

OBJECTIVE To evaluate the performance of the FreeStyle Libre Flash continuous glucose monitoring (FSL-CGM) system against established central laboratory methods. RESEARCH DESIGN AND METHODS 20 subjects (8 type 1 diabetes mellitus, 12 type 2 diabetes mellitus) were analyzed. FSL-CGM sensor measurements (inserted in arm and abdomen) were compared with capillary blood glucose results analyzed wi...

متن کامل

Experience with FreeStyle Libre Flash glucose monitoring system in management of refractory dumping syndrome in pregnancy shortly after bariatric surgery

Bariatric surgery is an effective therapy for obesity but is associated with long-term complications such as dumping syndromes and nutritional deficiencies. We report a case of a 26-year-old caucasian female, with history of morbid obesity and gestational diabetes (GDM), who became pregnant 4 months after Roux-en-Y bypass surgery. She developed GDM during subsequent pregnancy, which was initial...

متن کامل

Evaluation of the FreeStyle Lite Blood Glucose Monitoring System

Method: Clinical accuracy for fingertip capillary blood testing was assessed at three diabetes clinics with three lots of FreeStyle Lite test strips. At the same clinics, lay user performance and alternative site testing (on forearm, upper arm, palm thenar, palm hypothenar, back of the hand, calf and thigh) were also evaluated. FreeStyle Lite system results in these studies were compared to the...

متن کامل

Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes

Background/objectives In the current era of modern technology and the development of smart devices such as the flash glucose monitoring (FGM) systems, patients can easily monitor their glucose levels more frequently without any inconvenience. In this study, we evaluate the effect of FreeStyle Libre FGM system on glycemic control, hypoglycemia, health-related quality of life (QoL), and the fear ...

متن کامل

Accuracy, User Acceptability, and Safety Evaluation for the FreeStyle Libre Flash Glucose Monitoring System When Used by Pregnant Women with Diabetes

BACKGROUND Accuracy of the FreeStyle Libre™ Flash Glucose Monitoring System has not been evaluated in pregnant women with diabetes. The aim of this study was to determine accuracy (compared to self-monitoring of blood glucose [SMBG]), clinical safety, and acceptability of the FreeStyle Libre System when used at home by this population. MATERIALS AND METHODS Seventy-four participants, with typ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Diabetes

سال: 2018

ISSN: 0891-8929,1945-4953

DOI: 10.2337/cd17-0130