Free-breathing 3D cardiac function with accelerated magnetization transfer prepared imaging
نویسندگان
چکیده
منابع مشابه
Free-breathing 3D cardiac function with accelerated magnetization transfer prepared imaging
Background 3D cardiac MRI has long held promise for improved heart coverage, higher resolution, and reduced sensitivity to poor breath-hold reproducibility. However, its use has been limited by reduced blood pool to myocardium contrast for spoiled and balanced steady-state free precession (bSSFP) implementations. T2-preparation techniques [1] are capable of increasing contrast but are unfortuna...
متن کاملHighly Accelerated Free-breathing 4D Cardiac Imaging with CIRCUS Acquisition
INTRODUCTION 4D cardiovascular MRI applications typically require prolonged scan times and suffer from artifacts due to physiological motion. Compressed sensing (CS) and its combination with parallel imaging (PI) have recently emerged as valuable tools for accelerating MRI acquisitions by reconstructing images from undersampled k-space data. The required incoherent artifact in CS is usually ach...
متن کامل3D free-breathing cardiac cine imaging with respiratory and cardiac self-gating and 3D motion correction
INTRODUCTION Free-breathing cardiac cine imaging with respiratory and cardiac self-gating provides flexibility and convenience for patient scans. Here we propose a 3D radial cardiac cine imaging technique that improves upon self-gating by adding 3D respiratory motion correction. The 3D respiratory motion signals are derived from multiple projections through the data used for image reconstructio...
متن کاملFree-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging
Background Quantitative myocardial T1 mapping and extracellular volume fraction (ECV) show promise for non-invasive assessment of cardiomyopathies. Most available T1 mapping sequences use a single slice breath-hold acquisition with balanced steady state free precession (b-SSFP) readout [1]. However, b-SSFP readout is sensitive to B0 field inhomogeneity and is potentially T2 dependent [1]. In th...
متن کاملMagnetization Transfer in Cardiac Truefisp Imaging
Session IX: Friday, February 2, 2007 307. MAGNETIZATION TRANSFER IN CARDIAC TRUEFISP IMAGING Oliver M. Weber, PhD, Klaus Scheffler, PhD, Oliver Bieri, PhD. University of Basel, Switzerland, Basel, Switzerland. Introduction: Recently, we showed that the rapid succession of high flip angle RF pulses in conventional balanced steady state free precession (bSSFP) sequences causes an on-resonancemagn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2014
ISSN: 1532-429X
DOI: 10.1186/1532-429x-16-s1-p63