Mitral valve replacement with mounted aortic valve homografts.
The clinical results of isolated mitral valve replacement with mounted aortic valve homografts undertaken in 29 patients is presented. In 15 of these patients haemodynamic evaluations were made before and after operation. The results attest to the haemodynamic suitability of the homograft aortic valve in the mitral position and it would appear from this initial study that there will be little d...
متن کاملAortic valve replacement with frame - mounted autologous fascia lata
Between June 1969 and August I970, 8o patients, aged 22 to 63 years, had lone aortic valve replacement with frame-mounted autologous fascia lata. The operative mortality was 3.8 per cent. Seventy-seven survivors have been followed for 3 to 4 years and 50 have had postoperative investigation. There have been 8 subsequent deaths, 3 from infective endocarditis, 4 from aortic regurgitation, and one...
متن کاملAortic valve replacement with frame - mounted autologous fascia
Between June 1969 and August I970, 8o patients, aged 22 to 63 years, had lone aortic valve replacement with frame-mounted autologous fascia lata. The operative mortality was 3.8 per cent. Seventy-seven survivors have been followed for 3 to 4 years and 50 have had postoperative investigation. There have been 8 subsequent deaths, 3 from infective endocarditis, 4 from aortic regurgitation, and one...
متن کاملUse of aortic valve homografts for aortic valve replacement.
One hundred sixty-nine patients underwent replacement of the aortic valve with an aortic valve homograft; of these patients 17 had concomitant commissurotomy or annuloplasty for an associated mitral valve lesion. Homografts were prepared by sterilization with beta-propiolactone solution and stored in Hanks' solution, or were prepared by sterilization with irradiation and stored at -70 C. Operat...
متن کاملUse of Aortic Valve Homografts for Aortic Valve Replacement
One hundred sixty-nine patients underwent replacement of the aortic valve with an aortic valve homograft; of these patients 17 had concomitant commissurotomy or annuloplasty for an associated mitral valve lesion. Homografts were prepared by sterilization with beta-propiolactone solution and stored in Hanks' solution, or were prepared by sterilization with irradiation and stored at -70 C. Operat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery
سال: 1971
ISSN: 0022-5223
DOI: 10.1016/s0022-5223(19)42043-6