Fracture simulation of a demountable steel-concrete bolted connector in push-out tests

نویسندگان

چکیده

Many bolted connectors were proposed for use in steel-concrete composite structures over the past few decades. This is because using could make assembly and disassembly of more convenient reusing dismantled structural components also improve sustainability. Lots static fatigue experimental tests on conducted but detailed finite element simulations including fracture rarely reported. paper presents a series demountable connector push-out tests, which was reported by authors this before. Damage models bolt concrete materials are incorporated to better understand behaviour failure mode tests. Direct tension bolts simulated calibrate stress-strain relationship material assumed pure shear modelled validate criterion used simulations. Results modelling indicate that friction force at interface accounts part resistance conducted. The load-slip curves can be approximately predicted incorporating damage considering an appropriate coefficient. effects model, clearance hole, pretension short performance discussed last.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Push-out tests on shear studs in high strength concrete

A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedd...

متن کامل

Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading

Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

A Simple Fracture Mechanical Interpretation of Size Effects in Concrete Fracture Toughness Tests

Concrete is a so called quasibrittle material which, despite predominantly elastic material response, exhibits in tension loading a stable non-linear fracture response, when tested under displacement control. The reason for the non-linearity is the development of a fracture process zone, in front of the crack, due to micro-cracking and crack bridging. The effect of the fracture process zone is ...

متن کامل

Mixed Mode Fracture in Reinforced Concrete with Low Volume Fraction of Steel Fibers

An investigation into the mixed mode fracture of steel fiber reinforced concrete (SFRC)beams with one percent volume fraction of steel fiber is presented. A series of notched beams withdifferent notch depths and locations are tested under three-point bending. The test results for apparentfracture toughness, crack trajectories, and fracture energy are presented. The crack paths for SFRCand plain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Engineering Structures

سال: 2021

ISSN: ['0141-0296', '1873-7323']

DOI: https://doi.org/10.1016/j.engstruct.2021.112305