FP151EVALUATION OF RENAL FUNCTION 48 HOURS AFTER CARDIAC RESYNCHRONIZATION THERAPY DEVICE IMPLANTATION PROCEDURE

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

cardiac resynchronization therapy device implantation in a patient with congenitally corrected transposition of great vessels

a 29-year-old woman was referred to our hospital due to exacerbation in dyspnea on exertion and easy fatigability. a known case of congenitally corrected transposition of the great vessels and congenital complete heart block, she had already received a permanent single-chamber pacemaker. decision was made to implant a biventricular pacemaker for the treatment of the failing heart. excellent cor...

متن کامل

Cardiac Resynchronization Therapy Device Implantation in a Patient with Congenitally Corrected Transposition of Great Vessels

A 29-year-old woman was referred to our hospital due to exacerbation in dyspnea on exertion and easy fatigability. A known case of congenitally corrected transposition of the great vessels and congenital complete heart block, she had already received a permanent single-chamber pacemaker. Decision was made to implant a biventricular pacemaker for the treatment of the failing heart. Excellent cor...

متن کامل

Cardiac Resynchronization Therapy Device Implantation in a Patient with Cardiogenic Shock under Percutaneous Mechanical Circulatory Support

65-year-old woman was admitted to our hospital with acute decompensated heart failure with reduced left ventricular ejection fraction and severe mitral regurgitation. Electrocardiography revealed a typical left bundle branch block and atrial fibrillation. Her condition deteriorated despite administering high-doses of inotropes and vasopressors. Pending a decision to therapy, venoarterial extrac...

متن کامل

Cardiac resynchronization therapy device implantation guided by electroanatomic mapping system when contrast medium infusion is contraindicated

Introduction The implantation of transvenous leads for pacemakers and defibrillators is traditionally performed using fluoroscopic guidance. When cardiac resynchronization therapy (CRT) is indicated, iodine contrast medium (ICM) infusion for coronary sinus (CS) branch visualization is also needed. Adverse reactions to ICM during cardiac catheterization and coronary interventions are common. Chr...

متن کامل

Pectoral nerves (PECS) and intercostal nerve block for cardiac resynchronization therapy device implantation

A 71-year-old man was scheduled to undergo cardiac resynchronization therapy device (CRTD) implantation. He was combined with severe chronic heart failure due to ischemic heart disease. NYHA class was 3 to 4 and electrocardiogram showed non-sustained ventricular. Ejection fraction was about 20% revealed by transthoracic echocardiogram. He was also on several anticoagulation medications. We plan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nephrology Dialysis Transplantation

سال: 2018

ISSN: 0931-0509,1460-2385

DOI: 10.1093/ndt/gfy104.fp151