Fourier X-ray Scattering Radiography Yields Bone Structural Information
نویسندگان
چکیده
منابع مشابه
Correlation of X-Ray Vector Radiography to Bone Micro-Architecture
Besides the overall mass density, strength of trabecular bone depends significantly on its microstructure. However, due to dose constraints in medical CT imaging, it is impossible to gain sufficient information about very fine bone structures in vivo on the micrometer scale. Here we show that a recently developed method of X-ray vector radiography (XVR), an imaging method which uses X-ray scatt...
متن کاملPXAMS--Projectile X-ray AMS: X-ray Yields and Applications
Characteristic x rays have recently been explored as a method for the detection and identification of ions in accelerator mass spectrometry (AMS) [H. Artigalas et al., Nucl. Inst. and Meth. B 92, 227 (1994); M. Wagner et al., Nucl. Inst. and Meth. B 89, 266 (1994)]. After analysis in the AMS spectrometer, the ions stop in an appropriately chosen target and the induced x rays identify the ions b...
متن کاملX-Ray Diffuse Scattering
In this research program, modern x-ray scattering techniques are used to study the structures and phase transitions in novel states of condensed matter. We have two principal experimental facilities. At M.I.T. we have three high-resolution computer controlled x-ray spectrometers using either a conventional or high intensity rotating anode x-ray generator. The angular resolution can be made as f...
متن کاملX-ray detectors for digital radiography.
Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital ra...
متن کاملMonte Carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during X-ray radiography for constant mAs and AEC techniques
Background: The purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the X-ray radiography for constant mAs and AEC techniques. Materials and Methods: The DOSXYZnrc was used to simulate radiation doses in two human femurs during diagnostic radiography. EGSnrc phantoms produced from actual CT images of human femurs were modified by adding seven micrometre ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiology
سال: 2009
ISSN: 0033-8419,1527-1315
DOI: 10.1148/radiol.2521081903