Four hour identification of Enterobacteriaceae with the API Rapid 20E and Micro-ID systems.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Four hour identification of Enterobacteriaceae with the API Rapid 20E and Micro-ID systems.

One hundred strains of Enterobacteriaceae were examined in parallel with the API Rapid 20E and Micro-ID commercial four hour identification systems. With the API Rapid 20E system 78% of the strains were correctly identified, 15% were not identified, and 7% were misidentified. The respective figures with the Micro-ID system were 74%, 11%, and 15%.

متن کامل

Rapid identification of Enterobacteriaceae with the micro-ID system versus API 20E and conventional media.

The Micro-ID system for rapid (4 h) identification of Enterobacteriaceae was evaluated by testing 433 enteric bacilli and 9 other gram-negative bacilli. Each isolate was identified with conventional tubed media and was also tested in the Micro-ID and API 20E systems. The overall accuracy of both systems was 97%. Micro-ID tests for the Voges-Proskauer reaction, indole and H2S production, and orn...

متن کامل

Comparison of Micro-ID and API 20E systems for identification of Enterobacteriaceae.

The Micro-ID 4-h identification system for Enterobacteriaceae was compared to the API 20E overnight method, using 230 fresh clinical isolates and 74 stock cultures. Agreement was 97.8% for the clinical isolates and 93.2% for the stock cultures. Eighty-seven percent of primary culture plates containing gram-negative rods yielded sufficient growth to perform the 4-h Micro-ID identification on the...

متن کامل

Rapid identification of Enterobacteriaceae by using noncommercial micro-tests in conjunction with API 20E profile data.

A total of 371 (97%) of 382 strains of Enterobacteriaceae representing 26 species were identified cheaply, accurately, and rapidly by using a test system based upon standard 96-well microdilution plates and the API 20E profile data.

متن کامل

Evaluation of the four-hour rapid 20E system for identification of members of the family Enterobacteriaceae.

A study was conducted to compare the API Rapid 20E 4-h system (API System S.A., France; commercially available in the U.S.A. under the name DMS Rapid E System; DMS Laboratories, Darts Mill, Flemington, N.J.), the API 20E 18- to 24-h system (Analytab Products, Plainview, N.Y.), and a conventional media system to measure the ability of each to identify members of the family Enterobacteriaceae. Co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Pathology

سال: 1985

ISSN: 0021-9746

DOI: 10.1136/jcp.38.10.1132