Four-dimensional Plan Optimization for the Treatment of Lung Tumors Using Pencil-beam Scanning Proton Radiotherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4.

This work proposes a generic method for modeling scanned ion beam delivery systems, without simulation of the treatment nozzle and based exclusively on beam data library (BDL) measurements required for treatment planning systems (TPS). To this aim, new tools dedicated to treatment plan simulation were implemented in the Gate Monte Carlo platform. The method was applied to a dedicated nozzle fro...

متن کامل

Golden beam data for proton pencil-beam scanning.

Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...

متن کامل

Robust Planning for a Patient Treated in Decubitus Position with Proton Pencil Beam Scanning Radiotherapy

A challenging case was reported for a patient treated in decubitus position with proton pencil beam scanning. A regular robust plan with the consideration of the uncertainties of translational alignment and range accuracy cannot ensure the target coverage as revealed in two verification computed tomography (CT) scans during the first week of the treatment. The irreproducibility of daily alignme...

متن کامل

Beam‐specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors

The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering...

متن کامل

A comparison of two pencil beam scanning treatment planning systems for proton therapy

OBJECTIVE Analytical dose calculation algorithms for Eclipse and Raystation treatment planning systems (TPS), as well as a Raystation Monte Carlo model are compared to corresponding measured point doses. METHOD The TPS were modeled with the same beam data acquired during commissioning. Thirty-five typical plans were made with each planning system, 31 without range shifter and four with a 5 cm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Cureus

سال: 2018

ISSN: 2168-8184

DOI: 10.7759/cureus.3192