Foundation Differential Settlement Included Time-dependent Elevation Control for Super Tall Structures
نویسندگان
چکیده
منابع مشابه
A New Analytical Solution for Determination of Acceptable Overall settlement of Heap Leaching Structures Foundation
There are some artificial and natural materials on foundation of heap leaching structures. Geomembrane liner is the most important artificial isolated layer of these structures. The thickness of this layer is about 1 to 2 mm. Foundation overall settlement of such structures changes the primary length of the geomembrane layer. If the strain of geomembrane is more than allowable one, the layer wi...
متن کاملTime dependent trust structures
The correct functioning of distributed IT-systems requires elaborate and efficient ways to control the user’s access to the system. Traditional global or hierarchical access control systems are not suitable for distributed systems with autonomous components, where each component needs to dynamically maintain and enforce its own access control policy. Furthermore, the potential participants are ...
متن کاملEnergy Efficient Structures: Reducing Energy Consumption in Super-tall Buildings - UAE Case study
Over the past few years , there has b een an increasing emphasis on designing low-energy-use buildings. Rising energy prices and clim atic impacts of energy generation are among the important reasons. Super-tall buildings can be sustainable vertical cities of tom orrow, because of their high aspect ratios, efficien cy with res pect to lan d use, and reduced transportation and inf rastructure se...
متن کاملBenefits of geosynthetic reinforcement in widening of embankments subjected to foundation differential settlement
In the present study, physical model tests were conducted to investigate the effect of the geogrid reinforcement on the reduction of the differential settlement in widening of a highway embankment. A water bag filled with water and placed beneath an embankment was used to simulate the soft foundation of the widened portion of the embankment in the physical model test. Water from the water bag w...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of High-Rise Buildings
سال: 2017
ISSN: 2234-7224