Formula for computation of dose distributions around a 252Cf source.
نویسندگان
چکیده
منابع مشابه
A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...
متن کاملNew formula for Calculation of Cobalt-60 Percent Depth Dose
Introduction: On the basis of percent depth dose (PDD) calculation, the application of dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on ...
متن کاملStudy of the absorbed dose rate of all rays emitted from the 252Cf brachytherapy source by the Monte Carlo method
The 252Cf brachytherapy source is a spontaneous fission decay source, which is used as a neutron-emitting source. In addition to neutrons emitted from this source, gamma rays are also emitted with the average energy of 1 MeV. In this study, using the Monte Carlo N-Particle code (MCNPX), the absorbed dose rates of the neutrons, the primary gamma and the secondary gamma that generated by thermal ...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method.
Introduction: The commercial 252Cf sources are too large in size and clinical applications of neutron brachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, c...
متن کاملInvestigation of dose distribution 252Cf Isotron brachytherapy source based on TG-43U1 protocol by Monte Carlo method
Introduction:The commercial 252Cf sources are too large in size and clinical applications of neutronbrachytherapy (NBT) are limited to a small number of intracavitary treatments of cervical cancers. Recently, under the Cooperative Research and Development Agreement (CRADA) with Isotron Inc., the Oak Ridge National Laboratory (ORNL) encapsulated a new medical 252Cf sources, cal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1975
ISSN: 1884-4111,0033-8303
DOI: 10.3769/radioisotopes.24.4_235