Foreign-Body Reaction and Osteolysis in Dorsal Lunate Dislocation Repair With Bioabsorbable Suture Anchor
نویسندگان
چکیده
منابع مشابه
Glenoid osteolysis after arthroscopic labrum repair with a bioabsorbable suture anchor.
Bioabsorbable suture anchors are commonly used for arthroscopic repair of rotator cuff and labrum lesions. They provide soft-tissue attachment to bone. They have been introduced to avoid complications such as artefacts on MRI scans, commonly seen with metal anchors. However, bioabsorbable implants may lead to other problems such as local osteolysis, cyst formation, soft tissue inflammation and ...
متن کاملExtensive Osteolysis after the Use of a Bioabsorbable Suture Anchor: Case Report and Literature Review.
Bioabsorbable implants are very frequently used to treat rotator cuff and shoulder labrum injuries. Many researchers have observed small areas of osteolysis after treating pathological conditions of the shoulder using bioabsorbable anchors. Biological and mechanical theories have been put forward to account for the osteolysis caused by these materials. The case of a patient who was simultaneous...
متن کاملExtensive Osteolysis after the Use of a Bioabsorbable Suture Anchor: Case Report and Literature Review
Bioabsorbable implants are very frequently used to treat rotator cuff and shoulder labrum injuries. Many researchers have observed small areas of osteolysis after treating pathological conditions of the shoulder using bioabsorbable anchors. Biological and mechanical theories have been put forward to account for the osteolysis caused by these materials. The case of a patient who was simultaneous...
متن کاملIsolated Dorsal Dislocation of the Lunate
Lunate dislocations are well described in the volar direction as part of the perilunate dislocation, sometimes together with fractures of the other carpal bones or distal radius, as described by the anatomical studies of Mayfield [1]. It is a result of disruption of the complex inter-carpal and radiocarpal ligaments that hold the well conforming carpus in their normal position. Given the streng...
متن کاملCompound Dorsal Dislocation of Lunate with Trapezoid Fracture
We report about a dorsal dislocation of the lunate accompanied by a trapezoid fracture in a 41-year old male patient after a motorcycle accident. The lunate dislocation with no dorsal or volar intercalated segment instability (DISI, VISI) was diagnosed by x-ray whereas the trapezoid fracture was only diagnosable by computed tomography. A closed reduction and internal fixation of the lunate by t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: HAND
سال: 2016
ISSN: 1558-9447,1558-9455
DOI: 10.1177/1558944715627632